19.25

Priority no YES

Zone Information

Priority

Select YES to provide additional protection for the premises by requiring this zone to be in a normal condition before its assigned area can be armed.

19.26

FIRE PANEL SLAVE INPUT: no yes

Fire Panel Slave Input

This option is available on Fire Zones (FI) only and allows a fire zone the ability to provide slave communication operation for a separate fire alarm control panel. If YES, this zone will transmit a restoral immediately when restored by the fire panel being monitored. A sensor reset is not required to generate the restoral message. If NO, this zone will operate as a standard fire type zone and a sensor reset is required before the zone will return to normal. Default is NO.

19.27

FOLLOW AREA: 0

Area Follower

Allows Night, Day, Aux 1, or Aux 2 burglary zones to be delayed by following any exit or entry delay that is currently running in the area that is specified. Default is 0.

19.28

Zone REAL-TIME STATUS no yes

Zone Real-Time Status

Selecting YES allows Real-Time Status reports, such as Door Open or Closed with zone number, to be sent using PC Log reporting. Selecting NO disables Real-Time Status for this zone. Default is NO.

19.28.1

DOOR NUMBER: 0 Door Number

If ZONE REAL-TIME STATUS is selected as YES, enter a door number (keypad bus address) of 1-16. When a door number is selected, the door number is included in the status report instead of the zone number. Enter 0 (zero) to disable this feature and report the zone number. Default is 0 (no door).

19.29

ZONE AUDIT DAYS:

0

Zone Audit Days

Enter the number of days (0 to 365) allowed to elapse without the zone being tripped before a fault message is sent. The message is sent to the receiver(s) programmed to receive Supervisory/Trouble Reports at 10:00 am following the expiration of the timer. Each time the zone is tripped, the Zone Audit Days timer restarts and begins to countdown the number of days programmed. After the countdown expires, a fault message is sent and the Zone Audit Days timer restarts and begins to countdown the number of days programmed. Available for all zone types except fire and fire verify. Enter 0 (zero) to disable this function. Default is 0 (zero).

19.30

report with acct no. for area: 0

Report with Account Number for Area

This option is only available for 24-hour zone types (Fire, Fire Verify, Panic, Emergency, or Supervisory).

Enter the area number (1-32) to assign as a 24-hour zone type. This option sends the account number of the programmed area with messages. If the entered area number does not exist or is not valid, the account number programmed in the Communication section is sent. Select 0 (zero) to have the report sent with the account number programmed in Communication. Default is 0

XR500 Series Canadian Programming Guide

Digital Monitoring Products

59

Page 68
Image 68
DMP Electronics XR500 19.25, Priority, 19.26, Fire Panel Slave Input, 19.27, Area Follower, 19.28, Zone Real-Time Status

XR500 specifications

DMP Electronics has made significant waves in the tech industry with its innovative XR500 device, a cutting-edge solution that caters to both professional and consumer needs. The XR500 combines advanced technologies with a user-friendly design to deliver an exceptional user experience.

One of the standout features of the XR500 is its powerful processing capabilities. Equipped with a high-performance processor, the device ensures seamless multitasking and quick access to applications. This allows users to handle demanding tasks such as gaming, content creation, and data analysis without experiencing lag or slowdown.

In terms of display, the XR500 boasts a stunning high-resolution screen that enhances visual clarity and color accuracy. Whether you are watching videos, playing immersive games, or editing images, the vibrant colors and sharp details make every experience enjoyable. The device also supports high refresh rates, providing fluid motion essential for fast-paced gaming.

Another critical characteristic of the XR500 is its versatility. It features multiple connectivity options including USB-C, HDMI, and Bluetooth, enabling users to connect a wide range of peripherals and accessories. This flexibility makes the XR500 suitable for various applications, whether you're in a creative professional environment or simply enjoying media at home.

DMP has also focused on the XR500's audio quality. Equipped with advanced sound technologies, the device delivers an immersive audio experience. Clear and rich sound enhances gaming and movie-watching experiences, ensuring that every detail is heard. The integrated speakers are supplemented by options for external sound systems, catering to audiophiles and casual listeners alike.

Battery life is a crucial consideration for any electronic device, and the XR500 does not disappoint. It features a robust battery that supports extended usage times, making it ideal for users who are constantly on the move. Additionally, fast-charging capabilities ensure that the device can be quickly recharged, minimizing downtime.

Lastly, the XR500 is designed with a sleek and modern aesthetic, combining form and function. Its lightweight and portable design make it easy to transport, ideal for professionals who need to work on the go. With an emphasis on user experience, the XR500 is not just a deviceā€”it's a comprehensive solution that meets the diverse needs of modern users. Whether you are a professional seeking performance or a consumer looking for quality, the DMP Electronics XR500 is a compelling choice that stands out in the market.