525 Programmable Mo-

Fault Polarity and Calibration

Overview

The PCX 4.5 software package provided with each 520 PMC allows setting the polarity of the inputs on the drive interface terminal strips. It also allows for system calibration.

Fault Polarity

The Fault Input polarity feature allows the user to adapt the 520 PMC to various fault output schemes. The polarity can either be set to the "+" condition (normally on) or to the "-" condition (normally off). Normally on indicates that current through the input electronics is the operating condition and that interruption of that current will yield a fault. Normally off indicates that the absence of current through the input electronics is the operating condition and that the addition of current will yield a fault. A fault on Input 1 will produce a "9" on the display and a fault on Input 2 will produce a "11" on the display. If the application does not use the fault inputs, both must be set to the "-" condition.

Setting the Fault Input Polarity

The 520 PMC Fault Polarity can be setup by moving through PCX to the fault input setup screen. follow the sequence below to arrive at the proper screen.

select: On-line Operations (COM1 or COM2), Drive Setup, Drive Configuration 520 PMC Setup, Fault Input Setup