EMULEX MODEL 375 SAN STORAGE SWITCH

CHAPTER 2: SWITCH INSTALLATION

USERS GUIDE

System LEDs

The System LEDs indicate the switch’s status, independent of the port LEDs.

Fault

2 Gb/s

Figure 2-4: System LEDs

Power

Switch Operational

System LEDs

Indication

 

 

Fault

• When lit, one or more of the ports has failed or the internal temperature has

(yellow LED)

exceeded acceptable levels.

 

• When flashing, all ports are operational but another error has occurred.

 

Errors appear in an event log. The level of error severity that will cause

 

flashing to start can be controlled using the config sys fault command in the

 

CLI. The default is level 3, Critical.

 

Note: Whether lit or flashing, the switch will continue to operate. Switch

 

functionality may be impaired depending on the event that triggered the

 

Fault LED. Regardless of the cause, the switch requires immediate

 

attention.

 

 

Power

When lit, the switch is plugged in and the internal power supplies are functional.

(green LED)

 

 

 

2 Gb/s

When lit, the switch is set to operate at a speed of 2 Gb/s. When off, the switch

(green LED)

is set to 1 Gb/s.

 

 

Switch

• When lit, indicates that the switch has completed initialization for ports with

Operational

inserted SFPs and that the switch is operational.

(green LED)

• When flashing, the switch has been configured for multiple zones, and one or

 

more zones are up with at least one zone down.

 

If no zones (excluding hard zones) are operational, the LED turns off.

 

 

Port LEDs

The Port LEDs indicate the port’s status. Each port has two LEDs:

SFP Status LED

Port Bypassed LED

SFP Status

 

 

 

 

 

Port Bypassed

 

 

 

 

 

 

 

 

 

 

Figure 2-5: Port LEDs

 

 

 

 

 

 

 

 

SFP Status

Port Bypassed

 

 

 

LED

LED

Indication

 

 

(green LED)

(yellow LED)

 

 

 

 

 

 

 

 

Off

Off

Normal port operational status when an SFP is not installed.

 

 

 

 

 

 

 

Off

On or Flashing

The port is bypassed due to a faulty or improperly seated SFP.

 

 

 

 

After fixing this problem, power may need to be cycled before the

 

 

 

 

LED indication will change.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EMULEX CORPORATION

10

PART NUMBER 00041392-002 REV. B

Page 13
Image 13