Emulex 375 manual Troubleshooting Device Connections

Models: 375

1 77
Download 77 pages 30.48 Kb
Page 62
Image 62

EMULEX MODEL 375 SAN STORAGE SWITCH

USERS GUIDE

CHAPTER 4: TECHNICAL REFERENCE

CHAPTER 4

TECHNICAL REFERENCE

Troubleshooting Device Connections.........................59

Troubleshooting Management Connections ...............60

Port Bypass Conditions and Recovery .......................60

Default Smart Setting Attributes.................................61

Fibre Channel References .........................................62

TROUBLESHOOTING DEVICE CONNECTIONS

Problem

Recommended Action

 

 

SFP installed in one or

1. Verify that the power cord is firmly seated into switch and is connected

more ports but no

 

to a properly earthed receptacle (outlet).

LEDs lit

2.

Check the Power LED to ensure that the switch is turned on.

 

3.

Verify that the SFP is firmly seated.

 

 

SFP installed but only

Reseat the SFP. If the same condition occurs, the SFP is probably faulty

yellow LED is lit

and should be replaced.

 

 

 

SFP installed with

1.

Make sure that the device is powered on and operating properly.

both green and yellow

2.

Unplug the fiber cable from the node and verify that an optical signal is

LEDs lit

 

present on the cable receiver lead.

 

3.

Verify that the fiber cable is fully seated at either end.

 

 

If optical power meter is available, verify the device is transmitting a

 

 

signal.

 

 

If there is no signal present, the device may require rebooting, device

 

 

drivers may need to be reinstalled, or the HBA or disk controller

 

 

hardware may require servicing.

 

 

If a signal is present on both the cable lead and the end node, the HBA

 

 

or disk controller may require service.

 

4.

Ensure that the device and switch are operational and set to the same

 

 

speed.

 

 

SFP installed with only

The switch is receiving a valid signal from the device, but no upper level

green LED lit, but

protocols are active.

devices are not

1.

Verify that the proper HBA device drivers are loaded for the

communicating

 

appropriate operating system and that the host has been configured to

 

 

recognize attached disk devices.

 

2.

Improper FC-AL initialization could result from a defective or

 

 

inoperative adapter card or device. Run adapter diagnostics with a

 

 

loopback connector to see if the adapter is working properly.

 

3.

Unplug the fiber cable from the end node and verify that an optical

 

 

signal is present on the cable receiver lead. If no signal is present, the

 

 

cable’s receiver lead may be bad and the device may be streaming F8

 

 

Failure notifications.

 

 

 

EMULEX CORPORATION

59

PART NUMBER 00041392-002 REV. B

Page 62
Image 62
Emulex 375 manual Troubleshooting Device Connections