EMULEX MODEL 375 SAN STORAGE SWITCH

 

 

USERS GUIDE

APPENDIX C: EVENT MESSAGES

 

 

 

 

 

 

 

 

 

 

 

Event

Event Message

Severity

 

 

 

 

 

 

 

82

PORT is ready to be inserted

DBG

 

 

 

 

 

 

 

83

Segment stall on PORT #

NOTIFY

 

 

 

 

 

 

 

84

Bad Open on PORT #

WRN

 

 

 

 

 

 

 

85

Error during Port Disc.

NOTIFY

 

 

 

 

 

 

 

86

PORT PTBI failed due to timeout

NOTIFY

 

 

 

 

 

 

 

87

PORT changed to STATE

NOTIFY

 

 

 

 

 

 

 

88

Transceiver in PORT has been cycled

NOTIFY

 

 

 

 

 

 

 

89

PORT has cycled between insert/bypassed (not necessarily in that

NOTIFY

 

 

 

order)

 

 

 

 

 

 

 

 

90

Loop CYCLED on Port #

NOTIFY

 

 

 

 

 

 

 

91

Port exceeded Clk Delta threshold

INFO

 

 

 

 

 

 

 

95

Interframe has been received

INFO

 

 

 

 

 

 

 

96

Interswitch link added/removed

INFO

 

 

 

 

 

 

 

97

LIP Cycle Timeout

INFO

 

 

 

 

 

 

 

98

API Initialized OK

INFO

 

 

 

 

 

 

 

99

Selftest failure

ERR

 

 

 

 

 

 

 

100

Received Unknown event

INFO

 

 

 

 

 

 

 

101

CRC detected on either an ISL LIP or Generic Frame

NOTIFY

 

 

 

 

 

 

 

107

Trap task failed to update trap destination info.

CRIT

 

 

 

 

 

 

 

135

CLI level 1 password changed

NOTIFY

 

 

 

 

 

 

 

136

CLI level password changed to default setting

NOTIFY

 

 

 

 

 

 

 

150

WEB level 1 password changed

NOTIFY

 

 

 

 

 

 

 

151

Web password level changed to default setting

NOTIFY

 

 

 

 

 

 

 

165

System config reset to factory default

ERR

 

 

 

 

 

 

 

166

New Port Config Type added

NOTIFY

 

 

 

 

 

 

 

167

Port Config Type deleted

NOTIFY

 

 

 

 

 

 

 

168

Current Config saved to flash

NOTIFY

 

 

 

 

 

 

 

169

Error in saving config file to flash

ERR

 

 

 

 

 

 

 

170

Error in retrieving config information

ERR

 

 

 

 

 

 

 

171

Config File successfully configured system

NOTIFY

 

 

 

 

 

 

 

172

Error in initializing system with config file

ERR

 

 

 

 

 

 

 

198

A device tried to access another device that was not in the same

NOTIFY

 

 

 

zone

 

 

 

 

 

 

 

 

199

Health timer has expired on ZONE

NOTIFY

 

 

 

 

 

 

 

208

PORT is over threshold

NOTIFY

 

 

 

 

 

 

 

218

Trunk DOWN on PORT #

NOTIFY

 

 

 

 

 

 

 

219

Trunk UP on PORT #

NOTIFY

 

 

 

 

 

 

 

220

New Primary Trunk

NOTIFY

 

 

 

 

 

 

EMULEX CORPORATION

69

PART NUMBER 00041392-002 REV. B

Page 72
Image 72