EMULEX MODEL 375 SAN STORAGE SWITCH

CHAPTER 3: SWITCH MANAGEMENT

USERS GUIDE

Viewing Port Diagnostics

This page displays diagnostic information pertaining to each port in the switch. Use the information provided on this page to diagnose abnormally high error counts on a particular port.

To view the current diagnostic settings:

Click Advanced Functions > Diagnostics > Port.

The Port Diagnostics page appears.

Figure 3-30: Port Diagnostics page

Statistic

Description

 

 

Port & Health

Color Indicators

 

Green

 

Yellow

 

Red

 

See “Port Utilization and Health” on page 51 for descriptions of the health

 

indicators.

 

 

Insertion Count

Number of times this port has been inserted into the network since the

 

switch was reset or the counters were cleared.

 

 

CRC Errors

Number of CRC errors that are detected in frames passing through this port

 

since the switch was reset or the counters were cleared.

 

 

Ordered Set Errors

Number of Ordered Sets that are received on this port with an encoding

 

error since the switch was reset or the counters were cleared.

 

 

Clock Delta

Difference (in parts per million) between the internal switch clock and the

 

received clock signal on the port.

 

 

State

Current state of this port – either inserted or bypassed

 

 

Beacon Port

Forces both port LEDs to flash on and off continuously. Use this to locate

 

and take action on a specific port. The flashing overrides normal port

 

indication until beaconing is turned off; however, port operation continues to

 

operate normally.

 

 

 

EMULEX CORPORATION

55

PART NUMBER 00041392-002 REV. B

Page 58
Image 58
Emulex 375 manual Viewing Port Diagnostics, Port Diagnostics page appears