EMULEX MODEL 375 SAN STORAGE SWITCH

CHAPTER 2: SWITCH INSTALLATION

USERS GUIDE

 

 

 

 

 

 

 

 

 

 

 

 

SFP Status

Port Bypassed

 

 

 

LED

LED

Indication

 

 

(green LED)

(yellow LED)

 

 

 

 

 

 

 

 

Flashing

Off

Activity. Data is being transferred between the port and device.

 

 

 

 

 

 

 

On

Off

Normal operation but no activity. Port and device are fully

 

 

 

 

operational.

 

 

 

 

 

 

 

On

Flashing

Manually bypassed. A port can be manually bypassed using the

 

 

 

 

Web Manager’s Bypass Port feature.

 

 

 

 

 

 

 

On

On

Bypassed. SFP is installed but the port is not receiving a valid

 

 

 

 

signal or is receiving an F8 Failure notification from the attached

 

 

 

 

device.

 

 

 

 

 

 

 

Flashing

Flashing

Beaconing. This is set manually using the Web Manager or CLI.

 

 

 

 

 

 

Power Supply/Fan Module LED

The switch uses two power supply/fan modules to guarantee high availability with failover. Each power supply has a separate LED to indicate its condition.

Power Supply/Fan Module LED

Indication

(green LED)

 

 

 

On

No faults exist and AC power is supplied to the module.

 

 

Off

A power supply or fan fault has occurred in the module.

 

 

When a power supply or fan fault occurs, the switch will continue to operate normally as long as the faulty power supply/fan module remains installed in the switch and there are at least two fans operational in each module. If the power supply/fan module is removed from the switch, the switch will continue to operate normally for approximately 20-30 minutes. However, to guarantee continued operation, the malfunctioning module should be immediately replaced to maintain high availability.

Note: Keeping spare power supply/fan modules (Part Number 601319) in stock is highly recommended. Contact a sales representative for further information.