EMULEX MODEL 375 SAN STORAGE SWITCH

CHAPTER 3: SWITCH MANAGEMENT

USERS GUIDE

The Zone Initialization Master Port field displays the port number of the port that is currently assigned as the master for that particular zone. The Initialization Master is responsible for starting the change notification process in each zone.

To add ports to a zone:

1.Select the appropriate check boxes to place ports into zones.

2.Click Submit.

To activate zoning:

1. Select the Zoning Active check box near the bottom of the page.

Caution: Clearing the Zoning Active check box will deactivate all zones, which may degrade system performance or compromise security.

2. Click Submit.

To remove a port from a zone:

1.Clear the appropriate check box.

2.Click Submit.

To remove all ports from a zone:

1.Click Clear at the end of the row of check boxes for the appropriate zone.

2.Click Submit.

To remove all zones:

1.Click All under the Clear Zone heading.

2.Click Submit.

Single-Switch Zoning

The simplest zoning configuration is to place each port into a single zone, so that zones are separate from each other as shown in Figure 3-13.

Figure 3-13: Devices in a Single Zone

In Figure 3-13, zone 1 includes ports 1, 3, and 4, while zone 2 includes ports 2 and 5. Devices on ports 1, 3, and 4 have direct access to each other and devices on ports 2 and 5 have direct access to each other; however, devices 1, 3, and 4 are separated from devices 2 and 5.