EMULEX MODEL 375 SAN STORAGE SWITCH

APPENDIX C: EVENT MESSAGES

USERS GUIDE

APPENDIX C Event Messages

The event messages for the switch are listed below. For explanations, contact a customer service representative. The message’s applicable severity level as defined below is also provided.

Severity

Severity

Description

Level

 

 

 

 

 

1

EMERG

Immediate action required; system failing

 

 

 

2

ALERT

Unrecoverable condition reported; major event in progress

 

 

 

3

CRIT

Event failed with possible loss of integrity

 

 

 

4

ERR

Condition failed; action required

 

 

 

5

WRN

Failed event occurred; no action required

 

 

 

6

NOTIFY

Configuration error or abnormal event occurred; no action required

 

 

 

7

INFO

Event occurred; no action required

 

 

 

These severity levels can be used to designate which events trigger trap messages. Use the Command Line Interface (CLI) to designate the minimum severity level of events to be logged in the Event Log and at which severity level to illuminate the switch’s Fault LED.

 

Event

Event Message

Severity

 

 

 

 

 

 

 

1

Message log cleared

INFO

 

 

 

 

 

 

 

5

Power Supply # Failed

ALERT

 

 

 

 

 

 

 

6

Power Supply # Online

NOTIFY

 

 

 

 

 

 

 

7

Power Supply # Removed

ALERT

 

 

 

 

 

 

 

8

Power Supply # Inserted

NOTIFY

 

 

 

 

 

 

 

9

Fan has stopped

EMERG

 

 

 

 

 

 

 

10

Fan has returned

ALERT

 

 

 

 

 

 

 

19

Temperatures over limit

ALERT

 

 

 

 

 

 

 

20

Temperature OK

INFO

 

 

 

 

 

 

 

50

SPF Overvoltage

EMERG

 

 

 

 

 

 

 

54

SOC has detected a CRC error in the EEPROM

NOTIFY

 

 

 

 

 

 

 

70

PORT # bypassed

NOTIFY

 

 

 

 

 

 

 

71

PORT # inserted

NOTIFY

 

 

 

 

 

 

 

72

Transceiver detected at port #

NOTIFY

 

 

 

 

 

 

 

73

Transceiver removed at port #

NOTIFY

 

 

 

 

 

 

 

74

SEOC occurred on PORT #

NOTIFY

 

 

 

 

 

 

 

75

Port exceeded OS threshold

NOTIFY

 

 

 

 

 

 

 

76

Port exceeded CRC threshold

NOTIFY

 

 

 

 

 

 

 

77

Loop UP on Port #

NOTIFY

 

 

 

 

 

 

 

78

Loop DOWN on Port #

NOTIFY

 

 

 

 

 

 

 

79

PORT received a LIP(F8)

WRN

 

 

 

 

 

 

 

80

PORT CRC Error detected in frame

WRN

 

 

 

 

 

 

 

81

PORT did not receive LIPF7) within timeout

WRN

 

 

 

 

 

 

 

 

 

 

 

 

 

EMULEX CORPORATION

68

 

 

PART NUMBER 00041392-002 REV. B

 

 

Page 71
Image 71
Emulex 375 manual Severity Description Level, Event Event Message Severity