EMULEX MODEL 375 SAN STORAGE SWITCH

CHAPTER 3: SWITCH MANAGEMENT

USERS GUIDE

Port Information

The following settings are available.

Setting

Description

 

 

Smart Setting Name

Displays the name of the Smart Setting. The Smart Setting name

 

will automatically appear in the text box when selected in the scroll

 

menu.

 

 

Smart Setting Type

The topology among switches for a port. Options include:

 

• Initiator or Target Port – the default setting. Should be used when

 

there are no links between switches.

 

• Tree Cascade – designates the port as a tree cascade port. Use

 

this setting when connecting multiple switches together in a tree

 

cascade configuration. Under most conditions, this setting will

 

result in acceptable performance.

 

• String Cascade 1 through String Cascade 4 – designates the

 

string cascade to which a port is assigned. String cascades

 

maintain fairness when two or more InSpeed-based storage

 

switches are serially cascaded. Switch performance may be lower

 

when compared to a tree cascade configuration.

 

 

Pre-Insertion Testing

The following settings are available.

Setting

Description

 

 

Enable Policies/Smart

This policy is the default operating mode for all ports and

Insertion

determines what the switch looks for prior to allowing a port to insert

 

into a zone. When the policy is enabled, an external device is sent

 

an F7 Initialization notification by the switch until an F7 Initialization

 

notification is received from the device. Once an F7 Initialization

 

notification is received, the port is inserted in the zone.

 

This policy takes precedence over all other policies. When this

 

policy is disabled, no additional policies are operational, and as long

 

as a port transmits a signal of the correct frequency and amplitude,

 

the port will be allowed in the zone.

 

 

Port Test Before Insertion

This policy ensures that a device on a port is a valid, standards-

 

compliant participant before allowing the device to be inserted into a

 

zone. The device must meet all of the FC-AL requirements along

 

with going through a complete change notification cycle. During the

 

change notification cycle, the device becomes the Initialization

 

Master (IM) and goes through the change notification phases. Once

 

the change notification cycle is complete, the device can be

 

inserted. This process ensures that a bad device is not allowed into

 

the zone.

 

 

EMULEX CORPORATION

33

PART NUMBER 00041392-002 REV. B

Page 36
Image 36
Emulex 375 manual Port Information, Pre-Insertion Testing, Following settings are available