Using LANVIEW

 

Table 4-1 LANVIEW LEDs (continued)

 

 

 

 

 

 

 

 

LED

Color

State

Recommended Action

 

 

 

 

 

 

RX/TX LED Indications in PoE Port Status Mode

 

 

 

 

 

 

 

 

 

RX/TX

Green/Off

There is a connection to a

None.

 

 

 

PD. There is 48 Vdc at the

 

 

 

 

 

RJ45 connector.

 

 

Off/Red

Port is off due to overload.

 

The attached device

 

exceeded maximum load

 

according to 802.3af

 

standard PoE device power

 

classification.

1.Check the attached PD to see if it is defective and drawing too much power for its Power Classification.

2.Check Ethernet cable from the PD for short circuits.

3.Contact Enterasys Networks for technical support.

 

Red/Off

Port is off due to PoE power

None

 

 

management. Port may be

 

 

 

 

turned off due to priority or

 

 

 

 

other administration

 

 

 

 

configuration.

 

 

 

 

 

 

RX/TX

Off/Off

Port is off for other reason.

1. There is no connection to a PD.

 

 

 

2.

If the DFE module is in an N5

 

 

 

 

chassis, ensure that the N5 is

 

 

 

 

turned on.

 

 

 

3.

If connected to an N-POE Power

 

 

 

 

System, ensure that it is turned on.

 

 

 

4.

If the power is being received from

 

 

 

 

an N-POE Power System, check the

 

 

 

 

48 Vdc power cable connection.

 

 

 

5.

Swap 48 Vdc power cable with a

 

 

 

 

known good one.

 

 

 

6.

If you still have a problem, contact

 

 

 

 

Enterasys Networks for technical

 

 

 

 

support.

 

 

 

 

 

DFE-Platinum Series Hardware Installation Guide 4-7

Page 65
Image 65