Connecting to the Network
DFE-Platinum Series Hardware Installation Guide 3-13
Connecting UTP Cables to DFE ModulesThefixedRJ45frontpanelconnectionsofthe7G4285‐49and7G4205‐72are10/100/
1000 Mbpsports.Theseportshaveinternalcrossovers,andsupportautomatic‐polarity
sensingwhenconfiguredforautomatic‐negotiation.
Ifautomatic‐negotiationisnotactivatedonaport,useastraight‐throughcablewhen
connectingaworkstationtotheport.Whenconnectinganetworkingdevicetotheport,
suchasabridge,repeater,orrouter,useacrossovercable.
Ifaportissetforauto‐negotiation,automatic‐polaritysensingisalsoactivated.
Automatic‐polaritysensingeliminatestheneedforacrossovercable,regardlessifthe
connectionistoanothernetworkdeviceoraworkstation.
TheRJ45fixedfrontpanelconnectorsofthe7G4285‐49and7G4205‐72alsosupport
PoE‐compliantconnectionstoPDs(powereddevices)thatrequire48Vdcthroughthe
UTPcabletooperate.Whenthe48VdcisavailablethroughthebackplaneofanN5
chassisorexternallyfromanN‐POEPowerSystem,youcanverifyifthereispowerat
eachportasdescribedlaterinthisprocedure.
Making the UTP Connections
ToconnectandverifyUTPcableconnectionstoRJ45ports(1through48or72),referto
Figure 3‐4andproceedasfollows:
1. EnsurethatthedeviceconnectedtotheotherendofthesegmentispoweredON.
2. InserttheRJ45connectoronthetwistedpairsegmentintotheappropriateRJ45port
connector.
Note: All RJ45 front panel ports on these DFEmodules support Category 5 Unshie lded
Twisted Pair (UTP) cabling with an impedance between 85 and 111 ohms. Category3
cable may be used if the connection is going to be used only for 10 Mbps.
Caution: To prevent damage to the equipment, do not connect the PoE supported ports
(1 through 48 or 72) to segments running between buildings. Keep connections to
equipment within the building.
Precaución: Para evitar que el equipo se dañe, no conecte los puertos PoE
(1 a 48 o 72) a segmentos que vayan de un edificio a otro. Mantenga las conexiones de
los equipos dentro del edificio.