SelecType Options

ON

OFF

When DSR (Data Set Ready) is off, the signal level is permanently set HIGH, allowing the printer to send data to the computer. For most communications purposes, this option should be set to OFF (signal level HIGH). When DSR is on, data is sent to the computer only when DSR is HIGH.

ON

OFF

When CTS (Clear To Send) is off, the signal level is permanently set HIGH. The factory setting is OFF (signal level is HIGH). This setting should be set to OFF for most communications purposes.

When CTS is on, data is sent to the computer only when CTS is HIGH.

1 to 99 (Kbytes)

The receive buffer option allows you to change the size of the printer’s input buffer. By choosing an appropriate buffer size, you can quickly transfer the contents of a file from the computer’s memory to the printer’s memory. The printer then prints the information from its own memory and frees up the computer for other tasks. The factory setting is 1K.

SelecType 3-31