Initial Configuration

The IPI 100 Series units must be connected to a MLC 226 IP MediaLink controller with a valid IP address. See the MLC 226 IP User’s Manual for information about configuring the MLC controller’s IP address.

The IPI 200 Series units have a factory default IP address of 192.168.254.254. This IP address must be changed to an address that will operate on your local network.

There are three ways to change the IP address setting:

Global Configurator

IPI 200 Series unit’s embedded Web pages

Address Resolution Protocol (ARP) command

Before you Begin

1. Obtain a valid IP address for your IPI 200 Series device from your A/V system’s network administrator.

2. Write down the unit’s MAC address (a 12-digit number) found on a label on the rear panel of the unit (ex: 00-05-A6-01-0A-74).

3. If the unit’s IP address has been changed from the factory default (192.168.254.254), before setting a new IP address, the default IP address must be restored by performing a Mode 4 reset:

RESET

RESET

IPI 200 Series

Left Side

a.Hold down the Reset button on the left side of the unit (see figure above) until the Power LED blinks twice (6 seconds), then release.

NThe Reset button is recessed. Activate it with an Extron Tweeker or similar tool.

b.Press and release the Reset button again within 1 second.

The Power LED blinks quickly four times, confirming the Mode 4 reset, which returns the unit to its factory default IP address.