SIS Programming and Control

The Extron MediaLink IP Intercom 201 and 204 modules can be remotely set up and controlled via a host computer or other device (such as a control system) by using the Extron Simple Instruction Set (SIS) commands, accessed via RS-232 or an Ethernet LAN connection.

NThe following SIS commands are for use with the IPI 201 and 201 models only. Refer to the MLC 226 IP Series User’s Manual for IPI 101/104 series SIS command and control information.

IPI RS-232 protocol:

38400 baud

8 data bits

1 stop bit

no parity

no flow control

NThe configuration port requires 38400 baud communication. This is a higher speed than many other Extron products use. If using HyperTerminal or a similar application, make sure the PC or control system connected to these ports is set for 38400 baud.

LAN port defaults:

IP address: 192.168.254.254

gateway’s IP address: 0.0.0.0

subnet mask: 255.255.0.0

DHCP: off

NThe IP Intercom (IPI) must be configured before use.

Host-to-IPI Communications

SIS commands consist of one or more characters per field. No special characters are required to begin or end a command sequence. When the IPI determines that a command is valid, it executes the command and sends a response to the host device. All responses from the IPI to the host end with a carriage return and a line feed (CR/LF = ]), which signals the end of the response character string. A string is one or more characters.

IPI-initiated Messages

If you are communicating with the IPI via RS-232 or via a verbose Telnet connection when a local event such as a front panel selection or adjustment takes place, the IPI responds by sending a message to the host. No response is required from the host. The IPI-initiated messages are listed here (underlined).

(c)Copyright 2007, Extron Electronics, IPI 201 V1.00, 60-809-00 ]

Mon Day, DD Mon YYYY HH:MM:SS

(c)Copyright 2007, Extron Electronics, IPI 204, V1.00, 60-810-00 ]

Mon Day, DD Mon YYYY HH:MM:SS

Vx.xx is the firmware version number.

The IPI sends the boot and copyright messages under the following circumstances:

If the IPI is off and an RS-232 connection is already set up (the PC is cabled to the IPI 204 series and a serial terminal emulation program such as HyperTerminal is open), the connected unit sends these messages via RS-232when it is first powered on.

B-2 IPI 100 and IPI 200 Series • SIS Programming and Control

Page 60
Image 60
Extron electronic IPI 100, IPI 200 manual SIS Programming and Control, Host-to-IPI Communications, IPI-initiated Messages