SIS Programming and Control
The Extron MediaLink IP Intercom 201 and 204 modules can be remotely set up and controlled via a host computer or other device (such as a control system) by using the Extron Simple Instruction Set (SIS™) commands, accessed via
NThe following SIS commands are for use with the IPI 201 and 201 models only. Refer to the MLC 226 IP Series User’s Manual for IPI 101/104 series SIS command and control information.
IPI RS-232 protocol:
•38400 baud
•8 data bits
•1 stop bit
•no parity
•no flow control
NThe configuration port requires 38400 baud communication. This is a higher speed than many other Extron products use. If using HyperTerminal or a similar application, make sure the PC or control system connected to these ports is set for 38400 baud.
LAN port defaults:
•IP address: 192.168.254.254
•gateway’s IP address: 0.0.0.0
•subnet mask: 255.255.0.0
•DHCP: off
NThe IP Intercom (IPI) must be configured before use.
Host-to-IPI Communications
SIS commands consist of one or more characters per field. No special characters are required to begin or end a command sequence. When the IPI determines that a command is valid, it executes the command and sends a response to the host device. All responses from the IPI to the host end with a carriage return and a line feed (CR/LF = ]), which signals the end of the response character string. A string is one or more characters.
IPI-initiated Messages
If you are communicating with the IPI via
(c)Copyright 2007, Extron Electronics, IPI 201 V1.00,
Mon Day, DD Mon YYYY HH:MM:SS
(c)Copyright 2007, Extron Electronics, IPI 204, V1.00,
Mon Day, DD Mon YYYY HH:MM:SS
Vx.xx is the firmware version number.
The IPI sends the boot and copyright messages under the following circumstances:
•If the IPI is off and an