SIS Programming and Control, cont’d

Command/response table for SIS commands

Command

ASCII (Telnet\⤀

URL Encoded

Response

Additional Description

 

(host to intercom\⤀

(host to intercom\⤀

(intercom to host\⤀

 

 

 

 

 

 

Relay functions

 

 

 

 

Force relay on

1*1O

1 %2A1 O

Rly 1 *1]

Turn relay on.

Force relay off

1*0O

1 %2A0 O

Rly 1 *0]

Turn relay off.

Toggle relay

1*2O

1%2A2O

Rly 1* X%]

Toggle relay on/off.

 

 

 

 

X% = 1 (on) or 0 (off).

Pulse relay

1*3*X6# O

1%2A3%2AX6# O

Rly 1 * X%]

Set relay’s pulse time (X6#) in

 

 

 

Rly 1 * X%]

20 ms increments from 1 (20 ms,

 

 

 

 

minimum) to 65535 (1310700 ms,

 

 

 

 

maximum).

 

 

 

 

Default pulse length is 25 = 500 ms.

NIf the verbose mode is enabled, there are two responses from the unit because the relay is pulsed. During a pulse, the relay is toggled to its opposite state and then back to the original state.

View the relay

1O

1O

Rly 1 * X%]

 

state

 

 

 

 

 

 

Front panel security lockout modes (executive modes\⤀

 

Off24

0X

0X

Exe 0]

Executive mode is off.

On24

1X

1X

Exe 1]

Executive mode is on.

View lockout

X

X

X20(]

X20(= Front panel lockout

mode status

 

 

 

(executive mode) status

 

 

 

 

0 = off/unlocked (default)

 

 

 

 

1 = on, disable/lock the front panel

Example:

X

X

0]

Executive mode is off.

 

 

 

 

Status commands

 

 

 

View all

11S

11S

shows responses to commands

voltage and

 

 

12S•13S•14S•15S•16S•20S ]

temperature

 

 

 

 

status

 

 

 

 

View +12 V

12S

12S

+X20^]

X20^= Voltage (in volts)

P/S voltage

 

 

 

 

View +5 V IR

13S

13S

+X20^]

 

receiver port

 

 

 

 

voltage

 

 

 

 

View +3.3 V

14S

14S

+X20^]

 

IP Link/FPGA

 

 

 

 

voltage

 

 

 

 

View +1.5 V

15S

15S

+X20^]

 

FPGA voltage

 

 

 

 

View internal

20S

20S

X20&]

X20&=Temperature in degrees

temp. status

 

 

 

Celsius (the response is 3 digits

including leading zeros)

B-8 IPI 100 and IPI 200 Series • SIS Programming and Control

Page 66
Image 66
Extron electronic IPI 100, IPI 200 manual Command/response table for SIS commands, +X20