31
Hardware Output mode will monitor the power supply current when any (and only) one of the fill valve, detergent diverter, water softener, wash/drain motor, drying fan is being operated, so do not run combinations of outputs.
If the current is too high or too low, a fault with a component is present, and the controller will beep with a long low tone repeated every second.
Different combinations of outputs can be switched on or off together, but the controller will prevent higher current drawing components such as the wash pump and the lid motors being turned on together.
Press START/PAUSE to advance to the next hardware output.
Press KEYLOCK to turn the currently displayed output on or off. If the green LED on integrated or blue LED on designer above start/pause button is displayed, then that output has been switched on, and if it is not displayed then that output is off.
Press POWER to exit at any time (all outputs will be switched off on exit).
The LCD display and touch switch panel LEDs are illuminated to correspond to a particular hardware device. The following table details the display order of the test.
LCD | Heav | Norm | Fast | Deli | Rinse | Hardware Output |
bL | Off | Off | Off | Off | On | Backlight |
Er | Off | Off | Off | On | Off | Element Relay (turns off after 5 seconds) |
Ld | Off | Off | Off | On | On | Lid Motors (will run up to 10 seconds) |
dd | Off | Off | On | Off | Off | Detergent Diverter Valve |
FU | Off | Off | On | Off | On | Fill Water Valve |
P1 | Off | Off | On | On | Off | Motor Wash direction |
P2 | Off | Off | On | On | On | Motor Drain direction 4200 rpm (times out after 255 seconds.) |
rd | Off | On | Off | Off | Off | Rinse Aid Dispenser (dispenses according to current user setting) |
dF | Off | On | Off | Off | On | Drying fan |
LE | Off | On | Off | On | Off | Rinse Aid and Salt Tank LEDs |
C1 | Off | On | Off | On | On | Water Softener Diverter Valve |
C2 | Off | On | On | Off | Off | Water Softener Brine Pump |
C3 | Off | On | On | Off | On | Water Softener Brine Valve |
A1 | Off | On | On | On | Off | Rinse Aid Pump (operates as a valve for diagnostic purposes only) |
oC | Off | On | On | On | On | Displays current water temperature. |
oE | On | Off | Off | Off | Off | Displays controller rail voltage |
(C3 is used in the factory to empty the water softener before the product is packed.)
WARNING: Take care when running individual components not to overload them. It is advisable to place some water in the tub before turning the element on.
Tub Home Sensor Test: At any time during HO test mode the Keylock symbol on the LCD display (Keylock LED on integrated badge) indicates the tub position. On = closed, off = open.
To skip to the next level, press POWER button: