Fisher & Paykel DD247, DD607 Rinse Aid Pump operates as a valve for diagnostic purposes only

Models: DD247 DD607

1 76
Download 76 pages 26.75 Kb
Page 31
Image 31
Rinse Aid Pump (operates as a valve for diagnostic purposes only)

31

Hardware Output mode will monitor the power supply current when any (and only) one of the fill valve, detergent diverter, water softener, wash/drain motor, drying fan is being operated, so do not run combinations of outputs.

If the current is too high or too low, a fault with a component is present, and the controller will beep with a long low tone repeated every second.

Different combinations of outputs can be switched on or off together, but the controller will prevent higher current drawing components such as the wash pump and the lid motors being turned on together.

Press START/PAUSE to advance to the next hardware output.

Press KEYLOCK to turn the currently displayed output on or off. If the green LED on integrated or blue LED on designer above start/pause button is displayed, then that output has been switched on, and if it is not displayed then that output is off.

Press POWER to exit at any time (all outputs will be switched off on exit).

The LCD display and touch switch panel LEDs are illuminated to correspond to a particular hardware device. The following table details the display order of the test.

LCD

Heav

Norm

Fast

Deli

Rinse

Hardware Output

-------------------------------------------------------------------------------------------

bL

Off

Off

Off

Off

On

Backlight

Er

Off

Off

Off

On

Off

Element Relay (turns off after 5 seconds)

Ld

Off

Off

Off

On

On

Lid Motors (will run up to 10 seconds)

dd

Off

Off

On

Off

Off

Detergent Diverter Valve

FU

Off

Off

On

Off

On

Fill Water Valve

P1

Off

Off

On

On

Off

Motor Wash direction 2200-2800 rpm (will not run if the tub is open)

P2

Off

Off

On

On

On

Motor Drain direction 4200 rpm (times out after 255 seconds.)

rd

Off

On

Off

Off

Off

Rinse Aid Dispenser (dispenses according to current user setting)

dF

Off

On

Off

Off

On

Drying fan

LE

Off

On

Off

On

Off

Rinse Aid and Salt Tank LEDs

C1

Off

On

Off

On

On

Water Softener Diverter Valve

C2

Off

On

On

Off

Off

Water Softener Brine Pump

C3

Off

On

On

Off

On

Water Softener Brine Valve

A1

Off

On

On

On

Off

Rinse Aid Pump (operates as a valve for diagnostic purposes only)

oC

Off

On

On

On

On

Displays current water temperature.

oE

On

Off

Off

Off

Off

Displays controller rail voltage

(C3 is used in the factory to empty the water softener before the product is packed.)

WARNING: Take care when running individual components not to overload them. It is advisable to place some water in the tub before turning the element on.

Tub Home Sensor Test: At any time during HO test mode the Keylock symbol on the LCD display (Keylock LED on integrated badge) indicates the tub position. On = closed, off = open.

To skip to the next level, press POWER button:

Page 31
Image 31
Fisher & Paykel DD247, DD607 service manual Rinse Aid Pump operates as a valve for diagnostic purposes only