Fisher & Paykel DD607, DD247 service manual Sub Code Faults

Models: DD247 DD607

1 76
Download 76 pages 26.75 Kb
Page 38
Image 38
6.1.1 Sub Code Faults

38

Fault Code

LED Display

Fault

Possible Causes

E8

Normal LED

Solenoid fault

Check the harness connections at each

 

 

 

 

solenoid

 

 

 

• Coil is open circuit

 

 

 

• Coil is short circuit

E9

Normal &

Microcontroller fault

Badge isolator ( if present)

 

Rinse LED

 

Detergent diverter valve

 

 

 

Check harness connections

 

 

 

MFB

 

 

 

Controller

EC

Normal & Fast

Communications error

Harness connections between the MFB

 

LED’s

 

 

and controller

 

 

 

MFB

 

 

 

Faulty top controller

 

 

 

Faulty bottom controller

U1

Heavy & Rinse

Water Supply

Water turned off

 

LED’s

 

Insufficient water supply pressure

 

 

 

• Blocked water softener filter (if fitted)

 

 

 

• Spilt rinse aid casuing over foam in tub

 

 

 

• Incorrect detergent being used

 

 

 

Motor rotor

 

 

 

• The machine is siphoning

 

 

 

• Inlet valve has failed

 

 

 

Controller

U4

Heavy & Fast

Other tub is faulting

The other tub has a fault which is

 

LED’s

 

 

preventing operation of that tub.

 

 

 

• No repair is required to the tub showing a

 

 

 

 

U4.

U6

Heavy, Fast &

Spray arm not detected

Spray arm not sitting on rotor

 

Delicate LED’s

 

Insufficent water pressure

 

 

 

 

 

6.1.1 Sub Code Faults

Sub code faults help identify a particular fault within the main E fault code. The sub code is found by pressing the START/PAUSE button while in the diagnostic display mode, the sub code is displayed momentarily (3 sec) on the LCD (if fitted) and on the secondary panel for integrated or flat door models.

Fault Code

Sub

LED

Fault

Possible Causes

 

Code

Display

 

 

 

E2

01

Rinse & Eco

motor not

• Obstruction in motor rotor housing

 

 

LED

rotating

Rotor seized

 

 

 

 

Hall sensor

 

02

Delicate &

motor drawing

• Short in motor winding

 

 

Eco LED

too much

Hall sensor

 

 

 

current

 

 

 

03

Delicate,

Motor not

Open circuit winding

 

 

Rinse & Eco

drawing

harness connection

 

 

LED

enough

• Motor rotor incorrectly installed

 

 

 

current

 

 

Page 38
Image 38
Fisher & Paykel DD607, DD247 service manual Sub Code Faults