Fisher & Paykel DD247, DD607 Remove the tub to gain access to the duct, refer section

Models: DD247 DD607

1 76
Download 76 pages 26.75 Kb
Page 71
Image 71
1.Remove the tub to gain access to the duct, refer section 9.6.

71

9.29Internal Duct and Elbow Removal (some integrated models only)

1.Remove the tub to gain access to the duct, refer section 9.6.

2.To remove the chassis duct tube, remove the 13mm nut to release the elbow and gently pull the tube from the elbow duct.

3.To remove the rear duct elbow, the product will need to be uninstalled and pulled forward from the joinery to gain access to the elbow. To release elbow from the chassis, squeeze the side tabs and pull outwards.

NOTE: When pulling the product forward out of the joinery, remember to feed the service and ducting pipes through the service holes to stop them from getting damaged.

4.The ducting insulated hose is attached to the rear elbow and ducted through the joinery.

NOTE: Refer to the product installation guide for more detailed installation information.

Elbow

Side Tab

Side Tabs

13mm Nut

Insulated Vent Hose

Page 71
Image 71
Fisher & Paykel DD247, DD607 service manual Remove the tub to gain access to the duct, refer section