Fisher & Paykel DD607, DD247 service manual Fan Housing Locking Tabs, Flap

Models: DD247 DD607

1 76
Download 76 pages 26.75 Kb
Page 50
Image 50
Fan Housing

50

Fault Code E6 -Fan Fault

1.Check the harness connections on the component and the controller for signs of any water damage, corrosion or arcing. Replace if damaged.

2.Check that the harness is securely connected at the controller.

3.Run the drying fan (dF) in “HO” mode (refer p30 & 31) for at least 30 seconds. The fan should

push air through the vent. The flap within the fan housing should open. To check if the flap is free to move, remove the locking tab, remove fan and the flap can be pushed upwards.

4.While running the fan is HO mode, if a long low tone is played at 1 second intervals this indicates the fan is faulty, replace the fan.

5.Once the new fan is replaced, follow step 3 and run the fan in HO mode for 30 seconds, there should be no tone played.

6.If the fan fault continues, replace the controller.

Fault Code E6 - Sub Code 02 - Under Current

Fan Housing

Locking Tabs

Flap

1.Check the harness connections at the controller

2.Run the new drying fan (dF) in “HO” mode (refer p30 & 31) for at least 30 seconds. While running the fan in HO mode, if a long low tone is played at 1 second intervals this indicates the fan is faulty.

3.If the fault continues, replace the controller.

Fault Code E6 - Sub Code 03 - Over Current

1.Run the new drying fan (dF) in “HO” mode (refer p30 & 31) for at least 30 seconds. While running the fan in HO mode, if a long low tone is played at 1 second intervals this indicates the fan is faulty.

2.If the fault continues, replace the controller.

Page 50