5.2.1 Diagnostic Mode

34

5.2 DishDrawer Diagnostics Wireless Badge Models

The diagnostics for the wireless badge models are accessed through the USER SETUP FUNCTION, to access the User Setup Function:

Open the tub

Press and hold the PROGRAM and START/PAUSE switches on the touch panel simultaneously for 5 seconds (ensure PROGRAM button is pressed first).

A beep will sound

The secondary touch panel will have between 1 - 5 LED’s on.

5.2.1 Diagnostic Mode

To enter this mode:

Enter the USER SETUP FUNCTION, refer 5.2.

Press the PROGRAM button 2 times to reach the END OF CYCLE BEEPS option. (Eco LED is on, other program LED’s either all on, or all off).

Wait 5 seconds.

Press and hold PROGRAM and START/PAUSE button’s on the secondary touch panel simulteneously for 5 seconds ( ensure PROGRAM button is pressed first).

The product will beep and all secondary touch panel LED’s are on.

Program Indicators

Eco Indicator

 

 

 

 

Program Button

Start/Pause Button

5.2.2 Display Mode

While running the diagnostic mode, press the PROGRAM button to skip to HARDWARE OUTPUT MODE (HO), or.

Press the START/PAUSE button to select the DISPLAY MODE.

Press the PROGRAM button to successively display (for 3 seconds each)

Current fault code, shown from Heavy through to Rinse LED’s, with Eco LED off.

Current fault sub code, shown from Heavy through to Rinse LED’s, with Eco LED on.

Previous fault code, shown on Heavy through to Rinse LED’s with Eco LED off.

Previous fault sub code, shown on Heavy through to Rinse with Eco LED on.

Press and hold START/PAUSE button for 5 seconds to exit the display mode to standby USER SETUP FUNCTION mode.

5.2.3 Hardware Output Mode (HO)

Press the PROGRAM button to skip to FAST CYCLE MODE (FC), or. Press the START/PAUSE button to enter HO mode.

Press PROGRAM button to successively select each hardware output device ( refer to p30 for device table). Press the START/PAUSE button to turn a device on or off.

Press and hold the START/PAUSE button for 5 seconds to exit HO mode and return to standby USER SETUP FUNCTION mode.