1.Remove the cutlery basket and rack from the tub.

62

9.11 Filter Plate

1.Remove the cutlery basket and rack from the tub.

2.Remove the drain filter assembly.

3.Rotate the filter plate locknut anti-clockwise to release the filter plate from the motor rotor assembly.

4.Lift the filter plate clear.

5.Refit in reverse manner, ensure the 3 legs are locked correctly to the motor rotor and the o-ring on top of the motor rotor is in place.

9.12 Motor Rotor

Locknut

Motor Rotor

O-Ring

1.Remove the filter plate (refer section 9.11)

2.Slightly lift the motor rotor lock ring at the pointer to disengage the lock tab under the chimney, then rotate the motor rotor anti-clockwise to release it from the motor housing and lift out.

3.The rotor assembly is not serviceable and if damaged should be replaced.

4.Refit in reverse manner, taking care to align the legs on the rotor with the slots in the motor housing. The rotor can only be placed in one position. The short leg goes into the middle slot on the housing.

Rotate

Direction

Pointer

Lock Tab