39
Fault Code | Sub | LED Display | Fault |
| Code |
|
|
E3 | 01 | Rinse & Eco | Over |
|
| LED’s | Temperature |
|
|
|
|
E4 | 01 | Rinse & Eco | Element time out |
|
| LED’s |
|
|
|
|
|
| 02 |
| Dropper resistor |
|
| Delicate & Eco | open circuit |
|
| LED’s |
|
|
|
|
|
E5 | 01 | Rinse & Eco | Not starting |
|
| LED’s |
|
|
|
|
|
| 02 | Delicate & Eco | No current |
|
| LED’s |
|
|
|
|
|
| 04 | Fast & Eco | Not stalling |
|
| LED’s |
|
|
|
|
|
E6 | 02 | Delicate & Eco | Under current |
|
| LED’s |
|
|
|
|
|
| 03 | Delicate, Rinse | Over current |
|
| & Eco LED’s |
|
|
|
|
|
E7 | 02 | Delicate & Eco | Under current |
|
| LED’s |
|
|
|
|
|
| 03 | Delicate, Rinse | Over current |
|
| & Eco LED’s |
|
|
|
|
|
E8 | 02 | Delicate & Eco | Under current |
|
| LED’s |
|
|
|
|
|
| 03 | Delicate Rinse | Over current |
|
| & Eco LED’s |
|
|
|
|
|
E9 | 04 | Fast & Eco LED’s | ADC error |
|
|
|
|
| 05 | Fast, Rinse & | PSU over voltage |
|
| Eco LED’s |
|
|
|
|
|
| 06 | Fast, Delicate & | software reset |
|
| Eco LED’s |
|
|
|
|
|
| 07 | Fast, Delicate, | Forced PSU |
|
| Rinse & ECO | shutdown |
|
| LED’s |
|
Possible Causes
•Temperature sensor
•Element track faulty
•Dropper resistor open circuit
•Wiring to lid motor
•obstruction
•Controller
•Open circuit lid motor
•Controller
•Obstruction
•Wiring
•Open circuit fan motor
•wiring
•Short circuit fan motor
•Seized fan
•Wiring to detergent diverter valve
•Open circuit coil
•Short circuit coil
•Wiring to solenoid
•Open circuit coil
•Short circuit coil
•Wiring to coil or controller
•Badge isolator
•controller
•Harness connections
•Corroded connection at controller
•Detergent diverter coil
•Controller
•Check all component terminals for damage caused by corrosion.
•Controller & MFB