Interface
(30) SET FEATURES (X’EF’)
The host system issues the SET FEATURES command to set parameters in the Features register for the purpose of changing the device features to be executed.
Upon receipt of this command, the device sets the BSY bit of the Status register and saves the parameters in the Features register. Then, the device clears the BSY bit, and generates an interrupt.
If the value in the Features register is not supported or it is invalid, the device posts an ABORTED COMMAND error.
Table 5.23 lists the available values and operational modes that may be set in the Features register.
Table 5.23 Features register values and settable modes
Features |
| Drive operation mode |
|
Register |
|
| |
|
|
| |
|
|
| |
X’02’ | Enables the write cache function. |
| |
X’03’ | Set the data transfer mode. | *1 |
|
X’05’ | Enables the advanced power management function. *2 |
| |
X’42’ | Enables the Acoustic management function. *3 |
| |
X’55’ | Disables read cache function. |
| |
X’66’ | Disables the reverting to | (*1) | |
X’82’ | Disables the write cache function. |
| |
X’85’ | Set the advanced power management mode to |
| |
X’AA’ | Enables the read cache function. |
| |
X’BB’ | Specifies the transfer of | ||
| commands. |
| (*1) |
X’C2’ | Disables the Acoustic management function. |
| |
X’CC’ | Enables the reverting to | (*1) | |
*1 Although there is a response to the command, nothing is done. |
| ||
| At |
| |
| Write cashe function | : Enabled |
|
| Transfer mode | : PIO | |
| Advanced power |
|
|
| management function | : Enabled |
|
| Acoustic |
|
|
| management function | : State keeping |
|
| Read cashe function | : Enabled |
|