Fujitsu MHU2100AT manual Response to hardware reset

Models: MHU2100AT

1 278
Download 278 pages 51.42 Kb
Page 242
Image 242

Operations

After the slave device receives the hardware reset, the slave device shall report its presence and the result of the self-diagnostics to the master device as described below:

DASP- signal: Asserted within 450 ms.

PDIAG- signal: Negated within 1 ms and asserted within 30 seconds.

The asserted PDIAG-signal is negated 30 seconds after it is asserted if the command is not received.

Reset-

Master device

Status Reg.

BSY bit

Slave device

 

Max. 31 sec.

Checks DASP- for up to

If presence of a slave device is

confirmed, PDIAG- is checked for

500 ms.

up to 31 seconds.

 

BSY bit

Max. 1 ms.

PDIAG-

Max. 30 sec.

 

DASP-

Max. 450 ms.

.

Figure 6.2 Response to hardware reset

Note: Master Device does not check the DASP signal assertion for 2ms upon receipt of hardware reset.

6-4

C141-E202-01EN

Page 242
Image 242
Fujitsu MHU2100AT manual Response to hardware reset