Interface

(45)WRITE DMA EXT (X’35’): Option (customizing)

Description

This command is the extended command of the WRITE DMA command. The LBA specification is increased from 28 bits to 48 bits, and the maximum number of sectors that can be transferred by a single command is changed from 100h to 10000h. Other command controls are the same as those of the WRITE DMA command.

At command issuance (I/O registers setting contents)

1F7h(CM)

0

0

 

1

 

1

0

1

0

1

1F6h(DH)

1

L

 

1

 

DV

xx

 

 

 

1F5h(CH) P

LBA (47-40)

 

 

 

 

 

 

 

1F5h(CH) C

LBA (23-16)

 

 

 

 

 

 

 

1F4h(CL) P

LBA (39-32)

 

 

 

 

 

 

 

1F4h(CL) C

LBA (15-8)

 

 

 

 

 

 

 

1F3h(SN) P

LBA (31-24)

 

 

 

 

 

 

 

1F3h(SN) C

LBA (7-0)

 

 

 

 

 

 

 

1F2h(SC) P

Sector count (15-8)

 

 

 

 

 

1F2h(SC) C

Sector count (7-0)

 

 

 

 

 

1F1h(FR) P

xx

 

 

 

 

 

 

 

 

 

1F1h(FR) C

xx

 

 

 

 

 

 

 

 

 

C:Current

P:Previous

At command completion (I/O registers contents to be read)

1F7h(ST)

 

 

 

Status information

1F6h(DH)

1

L

 

1

DV

xx

1F5h(CH) 1

LBA (47-40)

 

 

 

1F5h(CH) 0

LBA (23-16)

 

 

 

1F4h(CL) 1

LBA (39-32)

 

 

 

1F4h(CL) 0

LBA (15-8)

 

 

 

1F3h(SN) 1

LBA (31-24)

 

 

 

1F3h(SN) 0

LBA (7-0)

 

 

 

1F2h(SC) 1

xx

 

 

 

 

 

1F2h(SC) 0

xx

 

 

 

 

 

1F1h(ER)

Error information

0: HOB=0

 

 

 

 

 

 

1: HOB=1

 

 

 

 

 

 

5-116

C141-E202-01EN

Page 192
Image 192
Fujitsu MHU2100AT manual Write DMA EXT X’35’ Option customizing Description