Fujitsu MHU2100AT manual Execute Device Diagnostic X’90’, Diagnostic code

Models: MHU2100AT

1 278
Download 278 pages 51.42 Kb
Page 106
Image 106

Interface

(9) EXECUTE DEVICE DIAGNOSTIC (X’90’)

This command performs an internal diagnostic test (self-diagnosis) of the device. This command usually sets the DRV bit of the Drive/Head register is to 0 (however, the DV bit is not checked). If two devices are present, both devices execute self-diagnosis.

If device 1 is present:

Both devices shall execute self-diagnosis.

The device 0 waits for up to 6 seconds until device 1 asserts the PDIAG- signal.

If the device 1 does not assert the PDIAG- signal but indicates an error, the device 0 shall append X’80’ to its own diagnostic status.

The device 0 clears the BSY bit of the Status register and generates an interrupt. (The device 1 does not generate an interrupt.)

A diagnostic status of the device 0 is read by the host system. When a diagnostic failure of the device 1 is detected, the host system can read a status of the device 1 by setting the DV bit (selecting the device 1).

When device 1 is not present:

The device 0 posts only the results of its own self-diagnosis.

The device 0 clears the BSY bit of the Status register, and generates an interrupt.

Table 5.4 lists the diagnostic code written in the Error register which is 8-bit code.

If the device 1 fails the self-diagnosis, the device 0 “ORs” X’80’ with its own status and sets that code to the Error register.

 

Table 5.4 Diagnostic code

 

 

 

Code

 

Result of diagnostic

 

 

 

X’01’

 

No error detected.

X’02’

 

HDC diagnostic error

X’03’

 

Data buffer diagnostic error

X’04’

 

Memory diagnostic error

X’05’

 

Reading the system area is abnormal

X’06’

 

Calibration abnormal

X’8x’

 

Failure of device 1

 

 

 

5-30

C141-E202-01EN

Page 106
Image 106
Fujitsu MHU2100AT manual Execute Device Diagnostic X’90’, Diagnostic code