5.3 Host Commands
(44)WRITE SECTOR(S) EXT (X’34’): Option (customizing)
•Description
This command is the extended command of the WRITE SECTOR (S) command. The LBA specification is increased from 28 bits to 48 bits, and the maximum number of sectors that can be transferred by a single command is changed from 100h to 10000h. Other command controls are the same as those of the WRITE SECTOR (S) command.
At command issuance (I/O registers setting contents)
1F7h(CM) | 0 | 0 |
| 1 |
| 1 | 0 | 1 | 0 | 0 |
1F6h(DH) | 1 | L |
| 1 |
| DV | xx |
|
|
|
1F5h(CH) P | LBA |
|
|
|
|
|
|
| ||
1F5h(CH) C | LBA |
|
|
|
|
|
|
| ||
1F4h(CL) P | LBA |
|
|
|
|
|
|
| ||
1F4h(CL) C | LBA |
|
|
|
|
|
|
| ||
1F3h(SN) P | LBA |
|
|
|
|
|
|
| ||
1F3h(SN) C | LBA |
|
|
|
|
|
|
| ||
1F2h(SC) P | Sector count |
|
|
|
|
| ||||
1F2h(SC) C | Sector count |
|
|
|
|
| ||||
1F1h(FR) P | xx |
|
|
|
|
|
|
|
|
|
1F1h(FR) C | xx |
|
|
|
|
|
|
|
|
|
C:Current
P:Previous
At command completion (I/O registers contents to be read)
1F7h(ST) |
|
|
| Status information | ||
1F6h(DH) | 1 | L |
| 1 | DV | xx |
1F5h(CH) 1 | LBA |
|
|
| ||
1F5h(CH) 0 | LBA |
|
|
| ||
1F4h(CL) 1 | LBA |
|
|
| ||
1F4h(CL) 0 | LBA |
|
|
| ||
1F3h(SN) 1 | LBA |
|
|
| ||
1F3h(SN) 0 | LBA |
|
|
| ||
1F2h(SC) 1 | xx |
|
|
|
|
|
1F2h(SC) 0 | xx |
|
|
|
|
|
1F1h(ER) | Error information | |||||
0: HOB=0 |
|
|
|
|
|
|
1: HOB=1 |
|
|
|
|
|
|