Interface

(48)WRITE LOG EXT (X’3F’) [Optional command (Customize)]

Description

This command writes data to the general-purpose log of a device. The general- purpose log includes the extended SMART comprehensive error log, extended self-test log, SMART selective self-test log, and other logs. However, some of these logs are read-only logs. The types of logs available depend on the customize operation. For information on the DRQ, INTRQ, and BSY protocols related to the transfer of data, see Section 5.4.1.

When command is issued (I/O register setting values)

1F7H (CM)

0

0

1

 

1

1

1

1

1

 

 

 

 

 

 

 

 

 

 

1F6H (DH)

x

x

x

 

DV

xx

 

 

 

 

 

 

 

 

 

 

 

 

 

1F5H (CH) P

xx

 

 

 

 

 

 

 

 

1F5H (CH) C

xx

 

 

 

 

 

 

 

 

1F4H (CL) P

Sector offset (15-8)

 

 

 

 

 

1F4H (CL) C

Sector offset (7-0)

 

 

 

 

 

1F3H (SN) P

xx

 

 

 

 

 

 

 

 

1F3H (SN) C

Log address

 

 

 

 

 

 

 

1F2H (SC) P

Sector count (15-8)

 

 

 

 

 

1F2H (SC) C

Sector count (7-0)

 

 

 

 

 

1F1H (FR) P

xx

 

 

 

 

 

 

 

 

1F1H (FR) C

xx

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C: Current

 

 

 

 

 

 

 

 

 

P: Previous

 

 

 

 

 

 

 

 

 

When command is completed (read data in I/O register)

1F7H (ST)

Status information

 

 

1F6H (DH)

x

x

x

DV

xx

1F5H (CH) 1

xx

 

 

 

 

1F5H (CH) 0

xx

 

 

 

 

1F4H (CL) 1

xx

 

 

 

 

1F4H (CL) 0

xx

 

 

 

 

1F3H (SN) 1

xx

 

 

 

 

1F3H (SN) 0

xx

 

 

 

 

1F2H (SC) 1

xx

 

 

 

 

1F2H (SC) 0

xx

 

 

 

 

1F1H (ER)

xx

 

 

 

 

0: HOB=0

 

 

 

 

 

1: HOB=1

 

 

 

 

 

5-120

C141-E202-01EN

Page 196
Image 196