Interface
5.6 Timing
5.6.1 PIO data transfer
Figure 5.9 shows of the data transfer timing between the device and the host system.
t0
Addresses
| t1 |
|
|
|
|
|
| t2 |
| t9 |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Write data |
|
|
|
|
|
|
|
|
|
|
|
|
| t2i |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| t3 | t4 |
|
|
|
|
|
| ||||
Read data |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| t5 |
|
| t6 |
|
|
|
|
|
|
| ||||||
IORDY | t10 |
|
|
|
|
|
|
| t11 |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
| t12 |
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| |||||||||||
Symbol | Timing parameter |
|
|
| Min. | Max. |
| Unit |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
t0 | Cycle time |
|
|
|
|
|
|
|
|
|
|
|
|
| 120 | — |
| ns |
| |
|
|
|
|
|
|
|
|
|
| |||||||||||
t1 | Data register selection setup time for |
|
|
| 25 | — |
| ns |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
t2 | Pulse width of |
|
|
|
|
|
|
|
|
|
|
|
|
| 70 | — |
| ns |
| |
|
|
|
|
|
|
|
|
|
| |||||||||||
t2i | Recovery time of |
|
|
| 25 | — |
| ns |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
t3 | Data setup time for DIOW- |
|
|
|
|
|
|
|
|
|
|
|
|
| 20 | — |
| ns |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
t4 | Data hold time for DIOW- |
|
|
|
|
|
|
|
|
|
|
|
|
| 10 | — |
| ns |
| |
|
|
|
|
|
|
|
|
|
| |||||||||||
t5 | Time from DIOR- assertion to read data available |
|
|
| — | 50 |
| ns |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
t6 | Data hold time for DIOR- |
|
|
|
|
|
|
|
|
|
|
|
|
| 5 | — |
| ns |
| |
|
|
|
|
|
|
|
|
|
| |||||||||||
t9 | Data register selection hold time for |
|
|
| 10 | — |
| ns |
| |||||||||||
|
|
|
|
|
|
| ||||||||||||||
t10 | Time from | — | 35 |
| ns |
| ||||||||||||||
|
|
|
|
|
|
| ||||||||||||||
t11 | Time from validity of read data to IORDY "high" level | 0 | — |
| ns |
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
t12 | Pulse width of IORDY |
|
|
|
|
|
|
|
|
|
|
|
|
| — | 1,250 |
| ns |
| |
|
|
|
|
|
|
|
|
| ||||||||||||
| Figure 5.9 | PIO data transfer timing |
|
|
|
|
|
|