Operations
6.1.4 Response to diagnostic command
When the master device receives an EXECUTE DEVICE DIAGNOSTIC command and the slave device is present, the master device checks the PDIAG- signal for up to 6 seconds to see if the slave device has completed the self- diagnosis successfully.
The master device does not check the DASP- signal.
After the slave device receives the EXECUTE DEVICE DIAGNOSTIC command, it shall report the result of the
PDIAG- signal: negated within 1 ms and asserted within 5 seconds
The asserted
When the IDD is set to a slave device, the IDD asserts the DASP- signal when negating the PDIAG- signal.
X'1F7' Reg.
Write
Master device
Status Reg.
BSY bit
Max. 6 sec.
If the slave device is preset, PDIAG- signal is checked for up to6 seconds.
Slave device
BSY bit
Max. 1 ms.
PDIAG-
DASP-
Max. 5 sec.