Table 5.15 Contents of SECURITY SET PASSWORD data

Word

 

Contents

 

 

0

Control word

 

Bit 0 Identifier

 

0

= Sets a user password.

 

1

= Sets a master password.

 

Bits 1 to 7 Reserved

 

Bit 8 Security level

 

0

= High

 

1

= Maximum

 

Bits 9 to 15 Reserved

 

 

1 to 16

Password (32 bytes)

 

 

17 to 255

Reserved

 

 

 

Table 5.16 Relationship between combination of Identifier and Security level, and operation of the lock function

Indentifier

Level

Description

 

 

 

User

High

The specified password is saved as a new user password. The lock

 

 

function is enabled after the device is turned off and then on.

 

 

LOCKED MODE can be canceled using the user password or the

 

 

master password already set.

 

 

 

Master

High

The specified password is saved as a new master password. The

 

 

lock function is not enabled.

 

 

 

User

Maximum

The specified password is saved as a new user password. The lock

 

 

function is enabled after the device is turned off and then on.

 

 

LOCKED MODE can be canceled using the user password only.

 

 

The master password already set cannot cancel LOCKED MODE.

 

 

 

Master

Maximum

The specified password is saved as a new master password. The

 

 

lock function is not enabled.

 

 

 