(2)LBA mode

Logical address assignment in the LBA mode starts from physical cylinder 0, physical head 0, and physical sector 1. The logical address is advanced at the subsequent sector from the last sector of the current track. The first physical sector of the subsequent physical track is the consecutive logical sector from the last sector of the current physical track.

Figure 6.6 shows an example of (assuming there is no track skew).

Physical sector

 

 

 

1

2

3

 

Physical cylinder 0

 

 

 

 

LBA

LBA

LBA

 

Physical head 0

0

1

2

 

 

 

 

 

 

1

2

3

 

Physical cylinder 0

 

 

 

LBA

LBA

LBA

 

Physical head 1

736

737

738

 

ex: Zone 0

Physical parameter

- Physical sector: 1 to 736

. . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . .

733 734 735 736

LBA LBA LBA LBA 732 733 734 735

733 734 735 736

LBA LBA LBA LBA 1464 1465 1466 1467

Figure 6.6 Address translation (example in LBA mode)

6.3Power Save

The host can change the power consumption state of the device by issuing a power command to the device.

6.3.1Power save mode

There are four types of power consumption state of the device including active mode where all circuits are active.

In the power save mode, power supplying to the part of the circuit is turned off. There are three types of power save modes:

Idle mode

Standby mode

Sleep mode

6 - 8