Fujitsu MPG3XXXAH-E manual Synthesizer circuit, Transfer rate of each zone, MPG3307AH-E

Models: MPG3XXXAH-E

1 201
Download 201 pages 38.92 Kb
Page 59
Image 59

4.6.4Synthesizer circuit

The drive uses constant density recording to increase total capacity. This is different from the conventional method of recording data with a fixed data transfer rate at all data area. In the constant density recording method, data area is divided into zones by radius and the data transfer rate is set so that the recording density of the inner cylinder of each zone is nearly constant. The drive divides data area into 15 zones to set the data transfer rate. Table 4.1 describes the data transfer rate and recording density (BPI) of each zone.

Table 4.1 Transfer rate of each zone

MPG3307AH-E

Zone

0

1

2

3

4

5

6

7

 

 

 

 

 

 

 

 

 

Cylinder

0

2208

4224

7232

9824

13120

15616

17088

 

to

to

to

to

to

to

to

to

 

2207

4223

7231

9823

13119

15615

17087

19359

 

 

 

 

 

 

 

 

 

Transfer rate

49.73

48.87

47.22

45.79

43.61

41.88

41.01

39.28

[MB/s]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

8

9

10

11

12

13

14

 

 

 

 

 

 

 

 

 

 

Cylinder

19360

22048

23840

25248

26592

28768

30176

 

 

to

to

to

to

to

to

to

 

 

22047

23839

25247

26591

28767

30175

30783

 

 

 

 

 

 

 

 

 

 

Transfer rate

37.22

35.77

34.62

33.45

31.43

30.12

27.92

 

[MB/s]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MPG3204AH-E / MPG3409AH-E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

0

1

2

3

4

5

6

7

 

 

 

 

 

 

 

 

 

Cylinder

0

2784

5568

8352

11264

13440

16096

17984

 

to

to

to

to

to

to

to

to

 

2783

5567

8351

11263

13439

16095

17983

19839

 

 

 

 

 

 

 

 

 

Transfer rate

60.71

60.71

60.71

60.71

59.22

56.86

54.90

52.94

[MB/s]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone

8

9

10

11

12

13

14

 

 

 

 

 

 

 

 

 

 

Cylinder

19840

22176

23584

25088

26720

28576

29952

 

 

to

to

to

to

to

to

to

 

 

22175

23583

25087

26719

28575

29951

30783

 

 

 

 

 

 

 

 

 

 

Transfer rate

50.35

48.82

47.06

45.10

42.75

40.94

38.04

 

[MB/s]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The MPU transfers the data transfer rate setup data to the RDC that includes the time base generator circuit to change the data transfer rate.

4 - 12

C141-E116-01EN

Page 59
Image 59
Fujitsu MPG3XXXAH-E manual Synthesizer circuit, Transfer rate of each zone, MPG3307AH-E