Servo frame

(96 servo frames per revolution)

Figure 4.5 Physical sector servo configuration on disk surface

(2)Servo burst capture circuit

The four servo signals can be synchronously detected by the DEMOD signal (internal), full-wave rectified integrated.

(3)A/D converter (ADC)

The A/D converter (ADC) receives the servo signals are integrated, converts them to digital, and transfers the digital signal to the DSP unit.

C141-E116-01EN

4 - 15

Page 62
Image 62
Fujitsu MPG3XXXAH-E manual Physical sector servo configuration on disk surface