6.1.4Response to diagnostic command
When the master device receives an EXECUTE DEVICE DIAGNOSTIC command and the slave device is present, the master device checks the PDIAG- signal for up to 6 seconds to see if the slave device has completed the
The master device does not check the DASP- signal.
After the slave device receives the EXECUTE DEVICE DIAGNOSTIC command, it shall report the result of the
PDIAG- signal: negated within 1 ms and asserted within 5 seconds then negated within 6 seconds.
When the IDD is set to a slave device, the IDD asserts the DASP- signal when negating the PDIAG- signal, and negates the DASP- signal when asserting the PDIAG- signal.
X'1F7' Reg.
Write
Master device
Status Reg.
BSY bit
Max. 6 sec.
If the slave device is preset, DASP- signal is checked for up to
6 seconds.
Slave device
BSY bit |
|
|
|
|
|
| ||||
|
| Max. 1 ms. |
|
| ||||||
PDIAG- |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
| Max. 5 sec. |
|
| ||||
|
|
|
|
|
|
|
|
| ||
DASP- |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
Figure 6.4 Response to diagnostic command
| 6 - 5 |