6.1.1Response to power-on
After the master device (device 0) releases its own
If the master device cannot confirm assertion of the DASP- signal within 450 ms, the master device recognizes that no slave device is connected.
After the slave device (device 1) releases its own
DASP- signal: Asserted within 400 ms, and negated after the first command is received from the host or within 31 seconds or after executing software reset, which ever comes first.
PDIAG- signal: Negated within 1 ms and asserted within 30 seconds, then negated within 31 seconds.
Power on
Master device
Power On Reset-
Status Reg. |
|
|
| |
|
|
| ||
BSY bit | Max. 31 sec. |
| ||
|
|
|
| |
|
|
| ||
| Checks DASP- for up to | If presence of a slave device is | ||
| 450 ms. | confirmed, PDIAG- is checked for | ||
|
| |||
|
| up to 31 seconds. |
Slave device
Power On Reset-
BSY bit
Max. 1 ms.
PDIAG-
DASP-
Max. 30 sec.
Max. 400 ms.
Max. 31 sec.
Figure 6.1 Response to power-on
6 - 2 |
|