Furuno 1823C manual Measuring range & bearing between two targets

Models: 1823C

1 260
Download 260 pages 55.31 Kb
Page 58
Image 58

2. RADAR OPERATION

2.17.2Measuring range & bearing between two targets

The procedure which follows shows how to measure the range and bearing between two targets, using the targets “A” and “B” in the figure below as an example.

1.Operate the trackball to place the cursor on the target “A.”

2.Press the [EBL/VRM] key to show the EBL/VRM soft keys.

3.Press the EBL1 ON soft key to turn on the EBL1.

4.Press the OFFSET soft key. The origin of EBL1 moves to the cursor position, which is marked with an “X.”

5.Rotate the [ENTER] knob so the EBL bisects the target “B.”

6.Push the [ENTER] knob, then press the VRM1 ON soft key.

7.Rotate the [ENTER] knob to place the VRM1 on the inner edge of the target “B.”

8.Look at the indications for VRM1 and EBL1 to find the range and bearing between the two targets.

9.To cancel the offset EBL, press the OFFSET key.

12/LP 3nm

H-UP

Target B

Target A

 

EBL1

Bearing and range

45.0° R

VRM1

319.9° M EBL

VRM

EBL1

ON

VRM1

ON

OFFSET

EBL2

ON

VRM2

ON

+ 359.9 ˚R 11.70

between target A and target B

7.121nm

nm

Measuring range and bearing between two targets

2-22

Page 58
Image 58
Furuno 1823C manual Measuring range & bearing between two targets, Measuring range and bearing between two targets