4. VIDEO SOUNDER OPERATION

4.12.2Bottom alarm

The bottom alarm sounds when the bottom echo is within the alarm range set. To activate the bottom alarm, the depth must be displayed. Note that the bottom alarm is turned on or off reciprocally with the bottom alarm on the plotter alarm menu.

1.Press the [ALARM] key to show the ALARM menu.

2.Use the trackball to select BOTTOM ALARM.

3.Press the EDIT soft key to show the bottom alarm window.

BOTTOM ALARM

°

ON

§0000.0-0000.0 ft

OFF

Bottom alarm window

4.Use the trackball to select ON or OFF as appropriate. For ON, enter alarm range with the trackball and numeric keys: Adjust the trackball to select digit; hit appropriate numeric key to enter value.

5.Press the ENTER soft key or push the [ENTER] knob to register setting.

6.Press the [ALARM] key to close the menu.

4.12.3Fish alarm

The fish alarm sounds when a fish echo is within the preset alarm range. Note that the sensitivity of the fish alarm can be set on the SOUNDER SYSTEM SETUP menu.

1.Press the [ALARM] key to show the ALARM menu.

2.Use the trackball to select FISH ALARM.

3.Press the EDIT soft key to show the fish alarm window.

FISH ALARM

°

ON §0000.0-0000.0 ft

OFF

Fish alarm window

4.Use the trackball to select ON or OFF as appropriate. For ON, use the trackball and numeric keys to enter range: Adjust the trackball to select digit; hit the appropriate numeric key to enter value.

5.Press the ENTER soft key or push the [ENTER] knob to register setting.

6.Press the [ALARM] key to close the menu.

4-21

Page 167
Image 167
Furuno 1823C manual Bottom alarm window, Fish alarm window