7. MAINTENANCE, TROUBLESHOOTING

7.5Simple Troubleshooting

This section provides simple troubleshooting procedures which the user can follow to restore normal operation. If you cannot restore normal operation do not attempt to check inside the unit. Any trouble should be referred to a qualified technician.

7.5.1General

 

General troubleshooting

 

 

If…

Then…

you cannot turn on the

check for blown fuse.

power

check that the power connector is firmly fastened.

 

check for corrosion on the power cable connector.

 

check for damaged power cable.

 

check battery for proper voltage output (10.8 to 31.2 V).

there is no response

turn off and on the power. If there still is no response the key may

when a key is pressed

be faulty. Request service.

7.5.2Radar

Requires a network radar.

Radar troubleshooting

If…

But…

Then…

you pressed the

nothing appears on the display

check that the antenna cable is

[POWER/BRILL] key

 

firmly fastened.

and the RADAR TX

 

check if radar source is correct.

soft key to show the

 

 

radar picture

 

 

marks, legends

no echo appears

check Tx fuse in the power cable.

appear

 

If it is blown, replace it.

the picture is not

check antenna cable.

updated or it freezes

 

for freeze up, turn the display unit

 

 

off and on again.

tuning is adjusted

sensitivity is poor

magnetron may need to be

 

 

replaced. Contact your dealer.

the range is changed

radar picture does not change

try to hit the [+] and [-] keys again.

 

 

turn off and on the display unit.

there is poor

adjust A/C SEA.

discrimination in range

 

 

the true motion

reselect true motion mode.

presentation is not

 

check if heading and speed are

working properly

 

input.

the range rings are

hit the RADAR DISPLY and

not displayed

 

RINGS soft keys to display them.