1. OPERATIONAL OVERVIEW

1.5.4Selecting image source

When more than one network radar or network sounder is connected to the equipment, you may select an image source for each as shown below. This is not necessary when only one network radar or network sounder is connected.

1.Press the [DISP] key.

2.Press any soft key to show the following display.

RADAR SOURCE

RADAR - - -

SOUNDER SOURCE SOUNDER -

IP APPRESS

172. 031. 003. 002

HOST NAME

RADAR - - -

SELECT SOURCE

EDIT

IF THERE IS MORE THAN ONE NETWORK RADAR OR ECHO SOUNDER, YOU MAY SELECT THE IMAGE SOURCES FOR DISPLAY.

RETURN

Select source menu

3.Use the trackball to select RADAR SOURCE or SOUNDER SOURCE as appropriate, then press the EDIT key.

RADAR SOURCE

SOUNDER SOURCE

RADAR - - -

SOUNDER-

Radar source

Sounder source

Radar source and sounder source windows

4.Adjust the trackball to select location and rotate the [ENTER] knob to set character.

5.Push the [ENTER] knob to set.

6.Press the [DISP] key to finish.

7.Turn the power off and on again.

Note: Source names are determined at installation. For example, the source names for radars in a two radar system might be “RADAR” and “RADAR1”.