4. VIDEO SOUNDER OPERATION

4.10.5Water temperature alarm

There are two types of water temperature alarms: WITHIN RANGE and OUT OF RANGE. The WITHIN RANGE alarm sounds when the water temperature is within the range set, and the OUT OF RANGE alarm sounds when the water temperature is higher or lower than the range set. Note that the water temperature alarm is turned on or off reciprocally with the water temperature alarm on the plotter menu.

1.Press the [ALARM] key to show the ALARM menu.

2.Use the trackball to select TEMPERATURE ALARM.

3.Press the EDIT soft key to show the temperature alarm window.

TEMPERATURE ALARM

WITHIN RANGE

°+000.0 - +000.0° F OUT OF RANGE

§+000.0 - +000.0° F OFF

Water temperature alarm window

4.Use the trackball to select WITHIN RANGE, OUT OF RANGE or OFF as appropriate. For WITHIN, use the trackball and [ENTER] knob to enter alarm range: Operate the trackball to select digit; rotate the [ENTER] knob to set value.

5.Press the ENTER soft key or push the [ENTER] knob to register setting.

6.Press the [ALARM] key to close the menu.

4-20

Page 166
Image 166
Furuno 1933, 1943, 1833 manual Water temperature alarm window