Furuno 1833, 1943 Measuring range by VRM, EBL/VRM soft keys, How to measure range with the VRM

Models: 1933 1833 1943

1 248
Download 248 pages 21.45 Kb
Page 47
Image 47

2. RADAR OPERATION

2.10.3Measuring range by VRM

1. Press the [EBL/VRM] key to display the EBL/VRM soft keys.

.250/

.125nm

319.9

° M

EBL

SP

 

 

VRM

H-UP

 

 

 

 

 

 

 

EBL1

ON

VRM1

ON

OFFSET

EBL2

ON

VRM2

ON

+ 359.9° R 0.277nm

EBL/VRM soft keys

2.Press the VRM1 ON (dotted ring VRM) or VRM2 ON (dashed ring VRM) soft key to select the desired VRM. The selected VRM’s indication, at the bottom of the screen, is highlighted.

3.Rotate the [ENTER] knob the place the VRM on the inside edge of a radar target. Read the VRM indication to find range to the target.

.250/

.125nm

319.9

° M

EBL

SP

 

 

VRM

H-UP

 

 

 

 

 

 

 

EBL1

ON

VRM1

ON

VRM1

 

(Dotted line)

OFFSET

 

EBL2

VRM2

ON

 

(Dashed line)

VRM2

 

ON

 

EBL1

EBL2

+

359.9° R

VRM1 range

---.-°R

---.-°R

VRM1

VRM2

 

0.277nm

 

0.119nm

0.242nm

 

Active marker is highlighted.

VRM2 range

How to measure range with the VRM

4. You may turn off the EBL/VRM soft keys by pressing the [EBL/VRM] key.