1.1.5Installing stays (anti-vibration measure)

Install stays from the top of the hull unit to the ship’s hull. The stays should be angle iron with a size of 75X75X9 mm or more and at least two pieces should be used; one each to ship’s bow and stern directions. Install if possible, two more stays in ship’s transverse direction.

Bow

Stay

Stay

Hull Unit

Proper installation of stays

Do not install the stays as shown below. Vibration-resistance effect is reduced since vibration is applied to the stays as rotation force. Install them horizontally.

 

Crossbeam

 

on ceiling

Stay

(wrong installation method)

Eye Bolt

Proper installation

Hull Unit

90

 

 

Proper and wrong installation of stay

Note: Install stays as shown above, otherwise the transducer may be damaged.

1-7

Page 15
Image 15
Furuno FSV-24S installation manual Installing stays anti-vibration measure, Bow Stay Hull Unit