Passing the cable through the bottom of the control unit

For permanent mounting ((2) and (3) above), the control cable can be passed through the bottom of the control unit. Do the steps in below.

1.Unfasten eight screws (M4) to remove the cover from the bottom of the control unit.

2.Unscrew two screws (M4x10) to remove the cable clamp.

3.Disconnect two connectors J1 and J2 from the circuit board.

4.Attach the cable to the control unit cover with the cable clamp (removed at step 2), two flat head screws (M4), flat washers, spring washers and nuts (hardware: supplied).

Screw

M4X8 (8 pcs.)

 

Previous cable hole

Clamp

Nut

Spring washer

 

 

Flar washer

 

Flat head screw

Fasten the cable with the clamp here.

Control unit, cover removed

5.Re-connect two connectors (disconnected at step 3) to the previous locations.

6.Fasten eight screws to attach the control unit cover.

7.Attach the connector seal (supplied) to the hole at the rear of the control unit.

8.Drill a hole to pass the cable from the bottom of the control unit through the tabletop. The diameter of the hole should be 30 mm.

9.Attach the connector seal (supplied) to the hole at the bottom of the control unit when the above modification is not done.

10.Fix the control unit referring to (2) or (3) on the previous page.

Cable

Cable

w/o KB fixing plate

w/ KB fixing plate

Control unit, side view

1-13

Page 21
Image 21
Furuno FSV-24S installation manual KB fixing plate