2.7.2Raise/Lower Control Box

Connect power cable (3φ) and the transceiver unit cable (10S2078) as shown below.

CN-C101

 

Connect the transceiver

cable (10S2078) to here.

 

Cable TPYCY-4

 

Sheath

TB-C101

Armor

Connect the power cable TPYCY-4

 

(Japan Industrial Standard) or the

 

equivalent to this board.

Vinyl

 

LED (Red)

sheath

For detection of phase reversal on

Conductor

3 phase power cable

S = 4 mm 2

 

= 2.55 mm

Confirm LED after completing the installation. The LED lights (in red) if power connection is correct. If it is off, turn off power from the mains switchboard, check the cable connection and recheck the LED. The hull unit does not work if this connection is wrong.

Normal phase: LED lights (in red).

Phase reversal: LED does not light.

Power cable (3φ) TPYCY-4

Cable from transceiver unit 10S2078

Raise/lower control box, cover removed