Furuno FSV-24S installation manual Data Sheet Dispaly Unit FSV-2400

Models: FSV-24 FSV-24S

1 104
Download 104 pages 3.07 Kb
Page 70
Image 70

DATA SHEET 2

DISPALY UNIT (FSV-2400 )

Check item

 

Contents

Check point

CK

Standard

Result

Judge

Software

Check software version on

Self-check

WC

 

 

 

version

the each board

display

 

 

 

 

 

 

DCON

1050714***

 

 

 

 

 

 

 

DUAL

1050703***

 

 

 

 

 

 

 

IFES

1050711***

 

 

 

 

 

 

 

KEY

1050685***

 

 

 

 

 

 

 

TRCPU 1050717***

 

 

 

 

 

 

 

TRX

1050665***

 

 

 

 

 

 

 

to 1050684***

 

 

 

 

 

TRANSCEIVER UNIT(FSV-241)

Check item

Contents

Check point

CK

Meter reading

Result

Judge

TX output

Check transmission output

Test points on

OS

See fig 1

 

 

 

power voltage at following

the TRX boards.

 

 

 

 

 

conditions:

 

 

 

 

 

 

 

 

 

1st

layer

 

 

 

 

 

Range: 1000m

 

2nd layer

 

 

 

 

 

TX setting: 9-9-9

 

 

 

 

 

 

 

 

 

 

3

rd

layer

 

 

 

 

 

Tilt: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4th layer

 

 

 

 

 

Stabilize.: OFF

 

 

 

 

 

 

 

 

 

 

5th layer

 

 

 

 

 

TX weight: all 1

 

 

 

 

 

 

 

6th layer

 

 

 

 

 

Measuring point

 

 

 

 

 

 

 

7th layer

 

 

 

 

 

TP108-137

 

 

 

 

 

 

 

8th layer

 

 

 

 

 

Measure peak-to-peak

 

 

 

 

 

 

voltage at 5ms from the

 

9th layer

 

 

 

 

 

leading edge of the

 

10th layer

 

 

 

 

 

transmission pulse.

 

11th layer

 

 

 

 

 

 

 

12th layer

 

 

 

 

 

There are 15 channels of

 

13th layer

 

 

 

 

 

TX_P/N on each TRX

 

14th layer

 

 

 

 

 

board. (Totally 600ch)

 

15th layer

 

 

 

 

 

 

 

16th layer

 

 

 

 

 

 

 

17th layer

 

 

 

 

 

 

 

18th layer

 

 

 

 

 

 

 

19th layer

 

 

 

 

 

 

 

20th layer

 

 

 

 

Fig 1 TX output power and B voltage

Normally, the output power voltage should read 1400Vp-p. However, it varies within ± 15% because of transducer impedance. B voltage is normally 120V at each transmission.

1400Vp-p

5ms

AP-3

Page 70
Image 70
Furuno FSV-24S installation manual Data Sheet Dispaly Unit FSV-2400