Procedure
1.Clean the hull unit flange,
2.(1200 mm stroke) Use 24 hex. bolts, 48 hex nuts, flat washers and spring washers to fasten the attachment flange to retraction tank.
(1600 mm stroke) 24 bolts have already been fitted. Use the bolts, 48 hex. nuts, flat washers and spring washers to fasten the attachment flange to retraction tank.
3.Place the
To install the attachment flange and the hull unit, see “1.1.4 Installing hull unit on retraction tank” on page
The sectional view for the attachment flanges are shown on the next two pages.
Hex. Bolt
Flat Washer
Hull Unit Flange | ||
| ||
Flat Washer |
| |
Spring Washer | ||
Hex. | Hex. Bolt | |
Flat Washer (M20) | ||
Nut | ||
|
Attachment Flange
Existing Tank
Flat Washer
Spring Washer
Hex. Nut
Attachment flange for 1200 mm stroke transducer, sectional view