3.4Other SYSTEM Menu Items

This section shows you how to set up external equipment. Default settings are underlined.

3.4.1INTERFACE SETTING menu

MENU

INTERFACE SETTING

QUIT

QUIT

NMEA 1 BAUD RATE: 4800 bps

NMEA 2 BAUD RATE: 4800 bps

CIF BAUD RATE

: 4800 bps

AUX BAUD RATE

: 19200 bps

EXT KP INPUT

: DISABLE

EXT KP OUTPUT

: NEGATIVE

INTERFACE SETTING menu

NMEA 1 BAUD RATE

Set the transmission rate for the NMEA 1 port. (2400 bps, 4800 bps, 9600 bps, 19200 bps)

NMEA 2 BAUD RATE

Set the transmission rate for the NMEA 2 port. (2400 bps, 4800 bps, 9600 bps, 19200 bps)

CIF BAUD RATE

Set the transmission rate for the CIF port. (2400 bps, 4800 bps, 9600 bps, 19200 bps) If the CS-120A is connected, select “2400 bps”.

AUX BAUD RATE

Set the transmission rate for the AUX port. (2400 bps, 4800 bps, 9600 bps, 19200 bps)

EXT KP INPUT

Select whether the KP signal from external equipment is used or not, and set the edge polarity. (DISABLE, POSITIVE, NEGATIVE)

Note: Set TX INTERVAL in H-SCAN SETTING menu to “0” for transmission with external kp signal.

EXT KP OUTPUT

Select the KP output logic, POSITIVE or NEGATIVE. (POSITIVE, NEGATIVE)

3-8