3.6.2Selecting the Net Sonde information
The net depth information from the Net Sonde can be entered from the FNZ port or CIF port. Depending on the input port, select the DIP switch setting as follows. The default setting is FNZ.
Input port | DIP switch S3 - #1 |
FNZ(default) | OFF |
CIF1 or NMEA2/CIF2 | ON |
S3 |
DCON Board (10P6900 or 10P6900S)
Note1: When the NMEA2/CIF2 port is used, the DIP switch
Note2: Do not change the setting of
3.6.3Selecting echosounder signal
There are two kinds of echosounder signals, AC signal and DC signal. Depending on the signal, select the jumper setting at J496 and J497 on the CONE board as follows. The default setting is AC. See page
Input port | Jumper |
ES1 | J497 |
ES2/NET | J496 |
Note: SIGOUT (AC signal) terminal and REC terminal (DC signal) in the output port are provided for FURUNO echosounder. Therefore, when using SIGOUT terminal, it is not necessary to change jumper setting.